 MPM-15CM Series
Ch Chassis M i Mount, 15W t Single, Dual & Triple Out AC/DC Power Supplies
Key Features:
* 15W Output Power * Universal 85-265 VAC Input * EN60950 Approved * Single, Dual & Triple Outputs * Meets EN55022 B * Meets IEC Safety Class II * Chassis Mount Case DIN Rail Mounting Kit Available!
Electrical Specifications
Specifications typical @ +25C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter Input Voltage Range Input Frequency Input Current Inrush Current EMI Safety Ground Leakage Current Conditions Min. Typ. Max. 85 265 47 440 See Model Selection Guide 115 VAC 15.0 230 VAC 30.0 Meets CISPR Pub. 22/FCC Class B 115 VAC 0.1 230 VAC 0.3 Units VAC Hz A Pk
mA Units
Output
Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation, Single Output Load Regulation, Dual, Triple Aux Output Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Over Voltage Protection Short Circuit Protection, Note 3 Overload Protection, Note 4 Conditions Min. Typ. Max. See Model Selection Guide See Model Selection Guide 1.0 2.0 VIN = Min to Max 0.2 1.0 IO = Min to Max 0.5 1.0 IO = Min to Max 2.5 5.0 5.0 VDC Output 1.5 1.8 All Other Outputs 0.8 1.0 115 VAC, 60 Hz 20 0.02 Zener Diode Clamp 120 Continuous (Autorecovery) Typ. 120% to 180% of Output Power Conditions Input to Output Input to Output, Flash Tested For 60S 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 4,700 100 Typ. Max.
% % % % %VP-P of VO mSec %/C % of VO
General
Parameter Isolation Voltage Isolation Test Voltage Isolation Resistance EMI/RFI EMC Compliance Units VAC VAC M EN 55022 Level B IEC/EN 61000-4-2 Level B IEC/EN61000-4-3 IEC/EN 61000-4-4 Level 3 2 kV IEC/EN 61000-4-5 Level 3 1kV/2 kV 100 kHz Units C C %
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Switching Frequency
Environmental
Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. Max. -25 +25 +71 -40 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient
Physical
Case Size, Chassis Mount Case Size, DIN Rail Option Case Material Weight 3.81 x 2.13 x 0.92 Inches (96.7 x 54.0 x 23.3 mm) 3.81 x 2.13 x 1.35 Inches (96.7 x 54.0 x 34.3 mm) Non-Conductive Plastic& Fiberglass (UL94-V0) 5.69 Oz (162g) Conditions Min. Typ. MIL HDBK 217F, 25C, Gnd Benign 280 IEN 60950, IEC 60950 IEN 60950, IEC 60950 IEC 61140 Class II Max. Units kHours
Reliability Specifications
Parameter MTBF Safety Standards Safety Approvals Safety Class
Model Selection Guide
Model Number MPM-15S-05CM MPM-15S-12CM MPM-15S-15CM MPM-15S-24CM MPM-15S-48CM MPM-15D-12CM MPM-15D-15CM MPM-15T-0512CM MPM-15T-0515CM Output 1 (Vout 1) Current (A) Voltage 115 VAC 230 VAC (VDC) Max. Min. 0.290 0.275 0.275 0.275 0.273 0.275 0.275 0.290 0.284 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 5.0 12.0 15.0 24.0 48.0 +12.0 +15.0 5.0 5.0 3.000 1.250 1.000 0.625 0.310 +0.625 +0.500 2.000 1.80 0.300 0.125 0.100 0.063 0.030 +0.063 +0.050 +0.200 +0.200 Input Current (A) Output 2 (Vout 2) Current (A) Voltage (VDC) Max. Min. Output 3 (Vout 3) Current (A) Voltage (VDC) Max. Min. Capacitive Efficiency Load (%, Typ)
(F, Max)
-12.0 -15.0 +12.0 +15.0
-0.625 -0.500 +0.200 +0.150
-0.063 -0.050 +0.020 +0.015
-12.0 -15.0
-0.200 -0.150
-0.020 -0.015
3,900 2,200 2,200 2,200 1,000 1,500 1,500 Note 5 Note 5
75 79 79 79 79 79 79 74 74
Other output combinations are available Contact the factory for details at: sales@micropowerdirect.com
Notes: 1. Load regulation is measured for an output change of 0% to 100% at nominal input line. For multiple output models, the loads are balanced. 2. Operation at no-load will not damage these units. However, they may not meet all specifications. 3. Output short circuit protection is provided by a "hiccup mode" circuit. The unit recovers automatically when the fault condition is removed. 4. Output overload protection is provided by a fold back current limiting circuit. 5. For triple output models, the maximum capacitive load for 5 VDC outputs is 2,200 F. For all other outputs it is 1,500 F. 6. The MPM-15CM series includes a built-in 2.0A/250 VAC fuse. It is recommended that an external 1.5A slow blow fuse also be used on the input for protection.
Derating Curve
Mechanical Dimensions, Chassis Mount Pin Connections
Pin Single Dual Triple 1 AC-Neutral 2 AC-Line 3 +Vo +Vo +Vo 2 4 NC NC +Vo 1 5 -Vo Common Common 2/3 6 NC NC -Vo 1 7 NC -Vo +Vo 3 NC = No Connection
A DIN Rail mounting kit is available Contact the factory for details at: sales@micropowerdirect.com
MicroPower Direct
www.micropowerdirect.com
*
Notes: * All dimensions are typical in inches (mm) * Tolerance x. = 0.01 (0.25) x.xx
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
*
FAX: (781) 344-8481
*
E-Mail: sales@micropowerdirect.com


▲Up To Search▲   

 
Price & Availability of MPM-15T-0512CM

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X